User Friendly
- Polo Clamp
Freely adjustable from left to right in both direction, allowing maximum use
of space.
- Indication of Battery Level
When Battery level falls to the Low, an Alarm goes off as a safety precaution.
- AC Power Indication
On light indicates that the battery is being recharged and that the power
is plugged in.
- VFD Display
Same as used in airlines, allows object to be easily distinguished at a distance.
Combined with 7-Segment, the display is toggled, so all settings can be seen
at a glance.
Optional Functions
- Remote Control - Warning singal for alarm D.RATE, T.VOL, Toggle
Safety Functions
- Alarms
Air in line, Occlusion, Door open, Low battery, completion, No drive, Insert
IV set
When the Alarm goes off, lamp will light and the situation will be indicate
on the VFD.
- Movement Indication Lamp
When injection mode is on, a green light will blink
Setup Mode
Press mode on display panel for sub-menu
- Select IV SET
- ADJ. IV SET-select +20% (ml/h) to adjust drup injectior according to Sap
set.
- Occlusion level set - Adjust level according to patient and drug used.
L:250~450mmHg M:300~700mmHg H:600~1000mmHg
- K.V.O set
- 1.0~1000 ml/h : Adjust level (1~10ml/h)
- 0.1~0.9 ml/h : Fixed level (0.1 ml/h)
- System Reset - Clears all setting values and restores of value.
- Exit
- Purge F. Rate - Select injection speed (1~1000 ml/h)
- Micro function -0.1~100.0 ml/h
Convenient Maintenance
Battery
- Battery can be changed by removing the bottom panel.
BIOF3000 General Specifications
Infusion
Flow Rate |
1~1000ml/h 1ml increments
0.1~100.0ml/h 0.1 ml increments |
Accuroacy |
±5% (Accuracy dependent on quality of IV set) |
Volume ilmit range |
1~9999.0ml in 0.1ml increments |
Volume infused |
0.1~9999.0ml in 0.1ml increments |
K.V.O Rate |
- 0.1~1000ml/h : Adjust level (1~10ml/h)
- 0.1~0.9ml/h : Fixed level (0.1ml/h) |
Compatible with All IV. Sets |
1. KV2531 2. MS500 3. BIA122 4. KV243T |
Mechanical
Pumping Mechanism |
Linear Peristaltic finger |
Occlusion Pressure |
250~1000mmHg |
Dimensions (W x D x H) |
98 x 215 x 220mm |
Weight |
Approx. 3.5Kg |
Power
Pumping Mechanism |
100~240VAC, 50/60Hz |
Battery |
Rechargeable Ni-MH |
Battery Operation |
2~3hrs (at 100ml/h) |
Battery Charging |
6hrs (Automatic durin normal operation) |
Feature
Purge |
1ml/h~1000ml/h Adjustable |
Remote Control |
(Optional) |
Memory Function |
|
IV Set Free Flow Protection |
|
Sound Adjustable |
|
I.V Set Adjustable |
+20% ~ -20% (ml/h) |
Alarms
Air in Line |
Occlusion |
Door open |
Low Battery |
Compietion |
No Drive |
Insert IV Set |
|